火范文>英语词典>primary winding翻译和用法

primary winding

英 [ˈpraɪməri ˈwɪndɪŋ]

美 [ˈpraɪmeri ˈwɪndɪŋ]

一次绕组;原绕组

电力

英英释义

noun

  • coil forming the part of an electrical circuit such that changing current in it induces a current in a neighboring circuit
    1. current through the primary coil induces current in the secondary coil
    Synonym:primary coilprimary

双语例句

  • The main circuit of protection equipment is a fast power electronic switch negatively paralleled on the side of test transformer primary winding, the control circuits are mainly composed of input circuit, amplifier, voltage comparator, timer, forming pulse circuit and strong trigger.
    该装置的主电路采用了反并联在试验变压器一次侧的快速电力电子开关,控制电路由信号输入电路、放大电路、电平比较电路、定时电路、脉冲形成电路和强触发电路等组成。
  • Some proposals are given: selecting TV with good excitation characteristic, reducing grounding number of TV in same network, keeping the symmetry of line-earth capacitance and paying attention to insulation coordination in neutral point of primary winding.
    电磁式TV在使用中应注意选用励磁特性好的产品、减少同一系统中TV中性点接地的数量、保持系统三相对地电容的对称性,同时注意高压绕组中性点的绝缘配合问题。
  • Considering the conditions as voltage at primary winding, shortcircuit forces of windings and turns for transformer were calculated with FEM coupling circuit method under the 2D symmetrical model.
    以此起始条件设定变压器原边电压激励,利用磁路-电路耦合有限元法建立了2D轴对称模型,计算了变压器原、副边线圈及各线匝短路电磁力。
  • And also, the compensation current in the orthogonal phase of the primary winding current injected into the primary winding can adjust the equivalent resistance of the primary winding independently.
    在补偿绕组中注入一个与主绕组电流相位正交的补偿电流,可以独立调节主绕组的等值电阻。
  • The strength calculation method and the structure of current transformer with U primary winding to fulfil the dynamic stability requirements are introduced, and some calculating examples are given.
    介绍了U形一次绕组电流互感器可满足动稳定要求的结构及强度计算方法,并给出了计算实例。
  • Situated within the coil's primary winding is the secondary winding.
    与初级绕组对应的是次级绕组。
  • Calculation of Dynamic Stability of Current Transformer with U Primary Winding
    U形一次绕组电流互感器的动稳定计算
  • Through various short-circuit current temperature rise test results, the transformer temperature, time, and a high degree of three curves, obtained directly within the thermal region transformer primary winding height of about 83.3%.
    通过在不同短路电流条件下的温升试验,得到了变压器内部的温度与时间、纵向高度之间的关系曲线,得出变压器内部热区域主要集中在约绕组自下而上高度的83.3%区域。
  • The High Tension ( HT) voltage is produced by mutual induction between the primary winding and the secondary winding, and the central soft iron core intensifies the magnetic field between them.
    通过初级绕组和次级绕组之间的互感产生出一个高电压,把两绕组联系起来的中心软体起导磁的作用,它把磁场集中起来。
  • The using ratio of the electric energy is greatly raised by using the feedback energy from the primary winding of the high frequency transformers.
    该电源采用双管正激的主电路结构,用高频变压器的电感取代了限流电阻,利用了高频变压器初级绕组的反馈电能,极大提高了电能利用率。